» Support Center » Knowledgebase » The hand control of my CGE scope is displaying No response 16 or No response 17. What’s wrong with my scope?
 The hand control of my CGE scope is displaying No response 16 or No response 17. What’s wrong with my scope?
Answer "No response" means that the hand control has lost communication with the electronics board within the base of the telescope.  The number following this message will indicate the address of the component that has lost communication. 16 indicates the azimuth or RA motor board, 17 the altitude (declination) motor board. Unfortunately, this number doesn't tell why the error has occurred.

There are several reasons why this error message would appear.  Insufficient power is the most common. Check your power supply.  If the DC battery is low, the scope will be unable to communicate with the base of the telescope.  If you are using an AC adapter, please make sure that the adapter is rated for an output of 12 volts DC at a minimum of 2500mA (2.5 Amps).  If your adapter puts out less current than 2500mA, the scope will not be able to communicate properly. Check all power connections including the power port pin for solid connectivity.

If you have a cable in the PC port that is not connected to anything, then this can also cause the messages to appear.

The next potential causes: the hand control, the motor control circuit board, the motors, or the cables-wiring-connectors in between.  Plug in the hand control to an AUX port and see if this eliminates the message. CGE DEC and RA cables are easy to check and swap around to see if it's these cables or their ports. If these quick fix ideas don't work, it’s best to send the pier, equatorial head and hand control back to Celestron for factory service.


Article Details
Article ID: 2027
Created On: Nov 10 2008 11:18 AM

 This answer was helpful  This answer was not helpful


Repair/RMA Procedure

 Search
 Login [Lost Password] 
Email:
Password:
Remember Me:
 
 Article Options