		<item>
			<title><![CDATA[My CGE mount will not move in the declination axis when attached to my SBIG ST-7 autoguider.]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=1757]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">This is a known bug with the SBIG ST-7 camera.&nbsp; Please visit the </font><a href="http://www.sbig.com/pdffiles/ST7SeriesRelayFix.pdf"><font size="3">Santa Barbara Instrument Group website</font></a><font]]></description>
		</item>
		<item>
			<title><![CDATA[How do I get a flashable hand control for my Celestron GOTO German equatorial mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=1921]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">You can obtain a replacement flash upgradeable hand control with SkyAlign technology for your Celestron GOTO German equatorial mount.&nbsp;<br /><br />Simply contact your dealer.&nbsp; Or go to Celestron.com]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE Schmidt-Cassegrain telescope (SCT) primary mirror has translucent, whitish streaks on it. What happened?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=1991]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><span style="font-family: Arial"><font size="3">While it could be from moisture condensing and running on your optics, most likely it is the grease in the baffle tube that has melted&nbsp; (separated) and l]]></description>
		</item>
		<item>
			<title><![CDATA[The CGE polar finderscope’s reticle pattern of constellations and stars doesn’t agree with the sky. What’s wrong?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=1998]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">Nothing. The CGE&rsquo;s polar finderscope has an etched pattern on a reticle in its optics to make quick polar alignment easier. In order to do this, the reticle puts together two patterns to make a pattern]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE hand control is stuck displaying “Initializing….”  What can I do?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2002]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3"><span style="font-size: 12pt; font-family: Arial">Make sure no buttons are stuck. If not, then you can try the following three steps yourself.</span><br /><br />First, power supply. Try an AC adapter that is]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE mount has binding in the RA axis. What do I do to fix this?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2026]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">With your clutches locked, push the counterweight shaft. It should move a small amount in order to allow the RA motor to work properly. If it doesn&rsquo;t move, you need to adjust the worm block inside the ]]></description>
		</item>
		<item>
			<title><![CDATA[The hand control of my CGE scope is displaying No response 16 or No response 17. What’s wrong with my scope?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2027]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">&quot;No response&quot; means that the hand control has lost communication with the electronics board within the base of the telescope.<span>&nbsp; </span>The number following this message will indicate the ]]></description>
		</item>
		<item>
			<title><![CDATA[How do I replace the CGE’s internal battery?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2028]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><span style="font-family: Arial"><font size="3">You need to remove the equatorial head and access the interior or the pier.<br /><br /></font></span><span style="font-family: Arial"><font size="3">Remove th]]></description>
		</item>
		<item>
			<title><![CDATA[How do I adjust my CGE’s RA and DEC switches?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2029]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">First, remove the RA motor housing cover (held on by 4 2mm hex head screws &ndash; you don&rsquo;t need to remove the Philips head screws). Access the DEC compartment by removing the corresponding screws for]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE mount keeps moving after I release the arrow button. Is this backlash?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2030]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">Yes, your scope is experiencing backlash, play in the drive gears. The CGE mount uses worm-driven gears and has minimal backlash. All telescopes have some backlash, as gears can&rsquo;t be too tight, prevent]]></description>
		</item>
		<item>
			<title><![CDATA[What do I need to know about maintaining the power, DEC, RA, AUX, AUTOGUIDE and HAND CONTROL ports on my CGE mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2031]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">Your CGE mount has 10 ports, one for power and the other 9 for mount functions and accessories. Here are some tips to keep them working well.<br /><br /></font></span><span style="font-family: Arial"><font s]]></description>
		</item>
		<item>
			<title><![CDATA[Can I autoguide with the CGE series mounts?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2032]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">The CGE mounts have an autoguider port on the pier.<span>&nbsp; </span>This port will directly interface with any of the SBIG (Santa Barbara Instrument Group) type autoguiders on the market.<span>&nbsp;&nbsp]]></description>
		</item>
		<item>
			<title><![CDATA[What is the AUX port on my CGE mount for?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2041]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">The AUX port can be used with the CN16 GPS accessory to get location and time information for your scope from the GPS satellite system.<br /><br />It can also be used to plug in the hand control if the regul]]></description>
		</item>
		<item>
			<title><![CDATA[What is the PC port on my CGE mount for?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2044]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">&nbsp;</font></span><span style="font-family: Arial"><font size="3">The PC port can be used with the MCUpdate software to flash or update the motor control (MC) firmware on your CGE <span>&nbsp;</span>mount.]]></description>
		</item>
		<item>
			<title><![CDATA[What should I know about my CGE tripod?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2045]]></link>
			<description><![CDATA[<p><span style="font-family: Arial"><font size="3">Because the CGE is big, it&rsquo;s important that the tripod lock screws be tight to safely hold the weight of the combined mount and optical tube.&nbsp;</font></span></p><p><span style="font-family: Aria]]></description>
		</item>
		<item>
			<title><![CDATA[How can I use GOTO APPROACH to minimize backlash with my CGE mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2051]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">MENU &ndash; SCOPE SETUP &ndash; GOTO APPROACH lets you choose the direction the scope will use when approaching an object during the final part of slewing. The best way to use it is to minimize backlash.&nb]]></description>
		</item>
		<item>
			<title><![CDATA[What is the overall procedure for polar alignment of my CGE mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2052]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">While polar alignment can be difficult, the CGE has a number of features to make it easier and accurate.</font></span><span style="font-family: Arial"><font size="3">&nbsp;<br /><br /></font></span><span sty]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE scope seems to have runaway slews at times, circling around to track or while doing GOTOs. Is this caused by meridian flip? What is meridian flip?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2054]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><span style="font-family: Arial"><font size="3">Most likely it is caused by meridian flip. Here's the explanation.<br /><br />The hand control is programmed to prevent the scope from running into the mount ]]></description>
		</item>
		<item>
			<title><![CDATA[How do I collimate my CGE Schmidt-Cassegrain telescope (SCT)?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2059]]></link>
			<description><![CDATA[<span style="line-height: 115%; font-family: Arial; font-size: 12pt">Collimation of a SCT is critical to getting the sharpest images possible, especially when viewing planets at high magnification.<span>&nbsp; </span>There are three stages to a really goo]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE acts strangely - slow slewing or going off the object when it’s looking high in the sky.]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2062]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">You are probably looking at an object or objects near the meridian. Because of the way the CGE German equatorial mount is designed, motions near the meridian are different than for other parts of the sky. Th]]></description>
		</item>
		<item>
			<title><![CDATA[I just set up my CGE and it is slewing in the wrong direction. What gives?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2064]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">While this could be several things, most likely it&rsquo;s your cables. Be sure the RA and DEC cable connections are not reversed!</font></span>]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE scope slews in the wrong direction. Is this an encoder problem?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2072]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">It could be an encoder problem. The encoder is a light-emitting diode (LED) device that measures how much the motor has turned. Try this general test of the encoders:<br /><br /></font></span><span style="fo]]></description>
		</item>
		<item>
			<title><![CDATA[The declination motion of my CGE mount is getting progressively slower - what’s wrong?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2076]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">It could be the cable or it could be the encoder for the DEC motor.</font></span><span style="font-family: Arial"><font size="3">&nbsp;<br /><br /></font></span><span style="font-family: Arial"><font size="3]]></description>
		</item>
		<item>
			<title><![CDATA[How accurate is my CGE’s alignment?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2077]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">Go to SCOPE SETUP-MOUNT SETTINGS to find out. CONE VALUE gives the cone error found once calibration stars were added to the alignment. It should be less than &frac12;-degree. You may need to shim between th]]></description>
		</item>
		<item>
			<title><![CDATA[What about PEC (periodic error correction) and my CGE?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2079]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><span style="font-family: Arial"><font size="3">Periodic error correction (UTILITIES-PEC) counteracts worm gear errors to prevent trailing and improve photographs. As the worm turns, irregularities in its s]]></description>
		</item>
		<item>
			<title><![CDATA[My time zone isn’t in SETUP TIME-SITE for my CGE. What do I do?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2160]]></link>
			<description><![CDATA[<font size="3"><span style="font-family: Arial">Time zones that are fractional &frac12; hour aren&rsquo;t in the current firmware. These include most of </span><span style="font-family: Arial">India</span><span style="font-family: Arial">, as well as all ]]></description>
		</item>
		<item>
			<title><![CDATA[Does the stated payload weight of my Celestron mount include the counterweights?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2245]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">No. The payload weight does not include the counterweights.<br /><br /></font></span><span style="font-family: Arial"><font size="3">The payload weight is defined by Celestron&rsquo;s engineering department ]]></description>
		</item>
		<item>
			<title><![CDATA[Why am I getting “This mount does not support the PECTool” when using my CGE, CPC, CGEM and CGE Pro mounts?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2249]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">All of these mounts do indeed support PEC and Celestron&rsquo;s PECTool.<br /><br /></font></span><span style="font-family: Arial"><font size="3">The reason you see this error message is because you are usin]]></description>
		</item>
		<item>
			<title><![CDATA[I’m upgrading my Celestron Advanced GT or CGE German equatorial mount (GEM) to firmware version GEM 4.15 or later.  How does the new firmware’s All-Star polar alignment work with my mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2257]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">All-Star polar alignment (All-Star) allows users to choose any bright star for polar alignment, freeing you from always having to use Polaris for this purpose.&nbsp;<br /><br /></font></span><span style="fon]]></description>
		</item>
		<item>
			<title><![CDATA[My CGE mount is moving in the wrong direction when I use the direction arrows. What is wrong? How can I change the direction of the direction buttons?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2266]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">You need to review and adjust the button direction logic in your hand control menu. <br /><br />The directions are made user-adjustable so you can match the direction the star moves in the eyepiece with the ]]></description>
		</item>
		<item>
			<title><![CDATA[Where can I download the unified ASCOM drivers for Celestron?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2284]]></link>
			<description><![CDATA[<span style="font-family: Arial; color: #333333; font-size: 12pt">Please go to this web page on the <font color="#000000">ASCOM Initiatives website:</font><br /><br /><a href="http://ascom-standards.org/Downloads/ScopeDrivers.htm" target="_blank" title="A]]></description>
		</item>
		<item>
			<title><![CDATA[How do I do a GOTO or alignment on the sun when it does not appear in the SOLAR SYSTEM list?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2292]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">Once you have your solar filter over the front of your scope, you can safely point it at the sun. However, as a safety feature, the sun does not appear in the hand control unless you enable it.<br /><br />Go]]></description>
		</item>
		<item>
			<title><![CDATA[Is there any way to run Celestron’s Window-based drivers and software on Macs?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2272]]></link>
			<description><![CDATA[<span style="font-family: Arial; color: #333333"><font size="3">The drivers and software used with most Celestron products&nbsp;are (as of Fall 2009) not compatible with Mac operating systems.<br /><br />Though Celestron provides no support for these work]]></description>
		</item>
		<item>
			<title><![CDATA[My Celestron software won’t run on my Windows 7 computer. Help!]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2340]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><span style="font-family: Arial"><font size="3">If you have NexRemote, HCupdate, MCupdate,PECTool compatibility issues, simply download the&nbsp;latest versions from Celestron&rsquo;s Manuals/Drivers page. ]]></description>
		</item>
		<item>
			<title><![CDATA[My computer crashed while updating the mount’s motor control firmware (MC) with MCupdate and now all I see on the hand control is either “Initializing”, other messages or a blank screen. Help!]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2348]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">A computer crash or communications break between your PC and the hand control during an MC update may result in either &ldquo;Initializing&rdquo;, blank screen, &ldquo;No Response 16&rdquo; or &ldquo;No Resp]]></description>
		</item>
		<item>
			<title><![CDATA[I have two scopes I want to use side-by-side or tandem with my Celestron CGE – CGE Pro – CGEM – Advanced GT mount. Can I do that?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2353]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><span style="font-family: Arial"><font size="3">Yes you can!<br /><br /></font></span><span style="font-family: Arial"><font size="3">Tandem support (the ability to turn the Dec axis 90 degrees and mount mu]]></description>
		</item>
		<item>
			<title><![CDATA[My autoguider port seems to have a problem. How do I check it?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2360]]></link>
			<description><![CDATA[<span style="font-family: Arial; font-size: 12pt">Issue a command to move your mount from your autoguider program or autoguider hand control (not to be confused with the scope&rsquo;s NexStar hand control).<br /><br />The movement is very small, so you ne]]></description>
		</item>
		<item>
			<title><![CDATA[I’m using my mount with an autoguider and getting mixed results. What are the best settings to use with Celestron mounts?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2387]]></link>
			<description><![CDATA[<span style="font-family: Arial"><font size="3">There are no official settings to use with Celestron mounts that support autoguiders (these scopes have ports that will directly interface with any of the SBIG (Santa Barbara Instrument Group) type autoguide]]></description>
		</item>
		<item>
			<title><![CDATA[What are the payload weights of Celestron mounts?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2400]]></link>
			<description><![CDATA[<span style="font-family: 'Arial','sans-serif'; font-size: 12pt">The payload weight is defined by Celestron&rsquo;s engineering/product development department as the load that is carried by the mount&rsquo;s dovetail clamp.<br /><br />These are the payloa]]></description>
		</item>
		<item>
			<title><![CDATA[Can all named stars listed in the hand control be used for alignment?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2415]]></link>
			<description><![CDATA[<font size="3"><span style="font-family: 'Arial','sans-serif'">No. Only stars brighther than or equal to magnitude 2.5 (bright stars) can be used for alignments with Celestron&rsquo;s NexStar computerized mounts.<br /><br />Even though there are about 250]]></description>
		</item>
		<item>
			<title><![CDATA[How do I use a third party periodic error correction (PEC) program like PEMPro with my Celestron mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2441]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">PEC data is stored on the motor boards in the GPS, CPC, CPC Deluxe, CGE, CGEM, CGEM DX&nbsp;and CGE Pro mounts in order to improve their drive accuracy. Using functions in the ha]]></description>
		</item>
		<item>
			<title><![CDATA[What are the instructions for getting my CN-16 or SkySync GPS working with my Celestron GOTO mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2454]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 10pt" class="MsoNormal"><span style="line-height: 115%; font-family: 'Arial','sans-serif'; font-size: 12pt">First, find the AUX<span>&nbsp; </span>port to plug it in on your mount. <br /><br />For the Advanced GT using the CN-16,]]></description>
		</item>
		<item>
			<title><![CDATA[When should I use the CALIBRATE MOUNT utility? What does it do?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2463]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">For Celestron&rsquo;s German equatorial GOTO mounts, this feature is found in the menu under UTILITIES. <br /><br />There are two functions in the CALIBRATE MOUNT submenu. Depend]]></description>
		</item>
		<item>
			<title><![CDATA[What dovetail bars are used with various Celestron mounts?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2464]]></link>
			<description><![CDATA[<font face="Arial" size="3">The most common dovetail bar size in the telescope market is the Vixen-style bar, which is 1-3/4&rdquo; wide. This is the size used with the dovetail clamp on the Advanced GT (CG-5) mount. It is also used with the LCM, SLT, SE ]]></description>
		</item>
		<item>
			<title><![CDATA[How do you stop a GOTO slew in progress? Is there a better way than turning off power or pulling the power plug?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2468]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">Interrupt the mount&rsquo;s GOTO slew by pressing any arrow key. The mount will halt the GOTO in progress.<br /><br /></font><font face="Arial" size="3">Since this is a regular h]]></description>
		</item>
		<item>
			<title><![CDATA[I want to use my CGE or CGE Pro mount with Software Bisque’s TPoint. How do I do this?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2470]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">TPoint and similar programs that model mount performance for pointing accuracy need the mount to start from the same position for each session.<br /><br />Home position for eithe]]></description>
		</item>
		<item>
			<title><![CDATA[The autoguiding port diagram in my scope's manual is different than the diagram for the NexGuide connection. Are these differences important?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2477]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">The differences are not really important.<br /><br />Here is the diagram for the NexGuide pinout requirements:<br /><img src="http://downloads.celestron.com/KB_images/port-con-Ne]]></description>
		</item>
		<item>
			<title><![CDATA[What problems are possible when using a dovetail-equipped  telescope tube designed for one mount when it’s used with another mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2486]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">The dovetail bar (sometimes called a rail) is one of the great ideas in small telescope design. With the clamp on the mount and a bar on the tube, telescopes (OTAs) and mounts ca]]></description>
		</item>
		<item>
			<title><![CDATA[What’s a quick summary of how to do All-Star polar alignment with CGEM – CGEM DX, CGE, CGE Pro and Advanced GT Series mounts?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2494]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">Here is a quick summary of All-Star polar alignment. It is basically the same for all the mounts. Some details differ: for example, the CGE and CGE Pro will not have index marks ]]></description>
		</item>
		<item>
			<title><![CDATA[Can I control my Celestron GOTO mount with programs like Maxim DL?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2582]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">Yes you can.<br /><br />Such programs connect to the mount via ASCOM (AStronomy Common Object Model). ASCOM provides a standard interface for a range of astronomy equipment inclu]]></description>
		</item>
		<item>
			<title><![CDATA[What battery type is used in the CGE mount for the real-time clock (RTC)?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2629]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">This mount uses the CR2032 3-volt lithium battery for the RTC.</font></p>]]></description>
		</item>
		<item>
			<title><![CDATA[What it is magnitude and meaning of the cone error readings given by Celestron German equatorial mounts?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2632]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">In the hand control menu under Scope Setup, Mount Settings, your Celestron GOTO German equatorial mount displays Cone Value, which is set when one or more calibration stars are a]]></description>
		</item>
		<item>
			<title><![CDATA[I’m experiencing motion in RA east after slews with my Celestron German GOTO mount. Is this backlash and how do I correct it?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2637]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font face="Arial" size="3">Yes, it is classic gear backlash.<br /><br />Gear backlash will often show up on the RA axis at rates above rate 2 when moving east. Worm gears will often show backlash of about ]]></description>
		</item>
		<item>
			<title><![CDATA[My equatorial GOTO mount seems to need a factory reset every now and the even though it otherwise works fine. Why is this?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2654]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font size="3"><font face="Arial">Your mount may normally perform just fine. Then while you are doing a two star alignment with calibration stars, the mount is way off when performing a goto to one of the c]]></description>
		</item>
		<item>
			<title><![CDATA[Will SkyQ Link work with the CGE mount?]]></title>
			<link><![CDATA[http://www.celestron.com/c3/support3/index.php?_m=knowledgebase&_a=viewarticle&kbarticleid=2661]]></link>
			<description><![CDATA[<p style="margin: 0in 0in 0pt" class="MsoNormal"><font size="3"><font face="Arial">No. Due to issues with the motor board circuitry in the mount, SkyQ Link cannot be used to control the CGE.</font></font></p><font face="Arial" size="3">&nbsp;</font>]]></description>
		</item>